A Study on Extraction of the Center Point of Steam Generator Tubes of YoungKwang Nuclear Power Plant

  • Published : 2002.10.01

Abstract

This paper describes extraction procedures for the center coordinates of steam generator tubes of Youngkwang nuclear power plant No. 6 unit. The centering coordinates of tubes are needed for monitoring whether ECT probe is exactly inserted into tube or not. However, The tube image tends to have poor contrast because steam generator bowl is sealed. The centering coordinates extraction procedure consists of two steps. The first step is to process the region with high contrast in entire image of steam generator tubes. Using the center points extracted in the first step and the geometry of tubes lined up in regular triangle patterns the centering coordinates of the rest region with low contrast...