Partitioning Interwell Tracer Test for NAPL Source Characterization: A General Overview

  • Lee, Tony R. (U.S. Environmental Protection Agency, Office of Research and Development, National Risk Management Research Laboratory, Subsurface Protection and Remediation Division) ;
  • A. Lynn Wood (U.S. Environmental Protection Agency, Office of Research and Development, National Risk Management Research Laboratory, Subsurface Protection and Remediation Division) ;
  • Jeong, Seung-Woo (National Research Council Research Associate)
  • 발행 : 2002.04.01

초록

Innovative and nondestructive characterization techniques have been developed to locate and quantify nonaqueous phase liquids (NAPLs) in the vadose and saturated zones in the subsurface environment. One such technique is the partitioning interwell tracer test (PITT). The PITT is a simultaneous displacement of partitioning and non-partitioning tracers through a subsurface formation. Partitioning tracers will partition into the NAPL during their transport through NAPL-contaminated formations. Mean travel times of partitioning and non-partitioning tracers are used to estimate the quantity of NAPL encountered by the displaced tracer pulse. Travel times are directly proportional to the partitioning coefficient and the volume of NAPL contacted in the subsurface environment. This paper discusses the conceptual background, design and implementation of PITTs. (This document has not been subjected to Agency review and therefore does not necessarily reflect the views of the Agency, and no official endorsement should be inferred.)

키워드