저온기 육용계사의 적정 환기체계 구명

  • Published : 2002.11.01

Abstract

The study was carried out to iind out the suitable ventilation system of the broiler house in winter season in Korea. Ammonia (NH$_3$-N) gas concentration (4.2ppm) of the system of pipe air inlet-forced chimney outlet was lower than that of the system of side wall inlet. The growth performance of broilers in the house equiped with pipe air inlet-chimney exhaust was higher than that of other ventilation systmes in which the average daily gain, feed efficiency and heat cost per head in the system of pipe air inlet-forced chimney excretion were 45.6g, 1.71 and 35.4 won per head, respectively. When the lengths of pipe air inlets were compared, the wind speed from the 4 meter-inlet was highest. The temperature of the broiler house equipped with the pipe air inlet system was higher (5.9 ∼ 7.7$^{\circ}C$) than that of the curtains in side wall Inlet system, in which the pipe air inlet system expects the lower heat cost.

환기체계별 내부환경 조사에서 입기관 입기 $\longrightarrow$ 강제 굴뚝배기방식이 NH$_3$ 농도 4.2ppm으로 윈치창 입기방식보다 유리하였고, 사육 성적에서는 입기관 입기 $\longrightarrow$ 강제 굴뚝배기방식이 일당 증체량 45.6g, 사료요구율 1.71, 수당 연료비 35.4원으로 다른 환기방식보다 우수하였으며, 입기관 길이별 풍속은 4m 가 1m 입기관보다 공기가 고루 퍼져가는 경향이었고 지점별 계사내 온도는 입기관 입기방식이 5.9 ~ 7.7$^{\circ}C$(평균 7.$0^{\circ}C$) 높아 연료절감 효과가 기대되었다.

Keywords