A Field Test on the Steady State Thermal Performance for the Forced Convection of Large Size Electric Air Heater

대형 전기온풍기 정상상태 열적성능의 현장시험에 관한 연구

  • 최창용 (전주대학교 공학부 기계공학과) ;
  • 김홍건 (전주대학교 공학부 기계공학과)
  • Published : 2002.10.01

Abstract

A field test was peformed to estimate the thermal performance of the forced convection electric air heater by the experiment. Air temperature, flow rate and electrical power input were measured with the related measurement sensors, and acquisition methods for the measured data were studied to effectively estimate the thermal performance of the tested air heater. To determine the mean air temperature at the flow cross-section, measuring positions were chosen by considering the flow velocity profile and the equally divided cross-sectional area. From the experimental results, thermal efficiency is obtained as an indication of the tested electric air heater performance.

Keywords