가스 터빈 블레이드 냉각 성능 향상을 위한 경사요철의 단락 효과

An Investigation of Angled Discrete Rib-Turbulators for Cooling Enhancement of Gas Turbine Blades

  • 우성제 (연세대학교 대학원 기계공학과) ;
  • 이세영 (연세대학교 대학원 기계공학과) ;
  • 조형희 (연세대학교 기계공학과)
  • 발행 : 2001.06.27

초록

Local heat/mass transfer and friction loss in a square duct roughened with various types of continuous and discrete rib turbulators are investigated. The combined effects of the gap flows of the discrete ribs and the secondary flows are examined for the purpose of the reduction of thermally weak regions and the promotion of the uniformity of heat/mass transfer distributions as well as the augmentation of average heat/mass transfer. The rib-to-rib pitch to the rib height ratio (p/e) of 8 and the rib angles of 90 and 60 deg are selected with $e/D_{h}=0.08$. The vortical structure of the secondary flows induced by the parallel angled arrays are quite distinct from that induced by the cross angled arrays. This distinction influences on heat/mass transfer and friction loss in all the tested cases. The gap flows of the discrete ribs reduce the strength of the secondary flows but promote local turbulence and flow mixing. As a result, the fairly uniform heat/mass transfer distributions are obtained with two row gaps.

키워드