Heat Transfer and Combustion Characteristics and Performance of U type Radiation Tube Burner with fin

핀 부착 U형 복사튜브 버너의 열전달 및 연소성능 실험

  • 이현찬 (한국가스공사 연구개발원 가스이용기술센터) ;
  • 유현석 (한국가스공사 연구개발원 가스이용기술센터) ;
  • 이중성 (한국가스공사 연구개발원 가스이용기술센터)
  • Published : 2001.06.27

Abstract

Present study deals with combustion characteristics and performance of U type radiation tube burner with fin which combustion capacity is 30,000kcal/hr and the maximum capacity of supply fuel is $30Nm^{3}/hr$. Temperature difference of radiation tube is about $173^{\circ}C$ at 25% capacity and this show relatively small temperature difference for convenient type. Thermal efficiency is satisfactory as $72{\sim}81%$. Also, radiative efficiency of radiation tube is $52{\sim}73%$. The efficiency of heat exchanger is $27{\sim}37%$. Therefore, radiative efficiency is improved to $1{\sim}10%$ after installing fin.

Keywords