파이프골조 온실의 조립연결구 내력에 관한 실험적 연구
Experimental Analysis on Yield Strength of Pipe Connectors and Joints for Pipe Framed Greenhouses
- 발행 : 2001.10.12
초록
Experiments on the yield strength of pipe connectors made of metal wire, joint pins, pole pipes, multi span insertion joints, and T-clamp joints used in pipe houses were conducted. The strength of connections of a pipe connector made of metal wire was adequate but it had a big difference according to loading direction. The collapse load of pipes connected with a joint pin was lower than that of single pipes. Also experimental results showed that pole pipes for use in a part of frame buried under the ground were safe, and the strength of multi span insertion joints should be increased. The resistant moment of T-clamp was about 13.7% of a single pipe.
키워드