대한전기학회:학술대회논문집 (Proceedings of the KIEE Conference)
- 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
- /
- Pages.115-117
- /
- 2001
변류기 포화검출 알고리즘을 적용한 모선보호용 비율전류차동 계전방식
A Percentage Differential Current Relaying Algorithm for Bus Protection Using Current Transformer Saturation Detecting Algorithm
- Kang, Yong-Cheol (Chonbuk National University) ;
- Yun, Jae-Sung (Chonbuk National University) ;
- Ok, Seung-Hun (Chonbuk National University)
- 발행 : 2001.11.16
초록
A percentage current differential relaying algorithm is widely used for bus protection. However, it may maloperate external faults with CT saturation. This paper proposes a percentage current differential relaying algorithm for bus protection using CT saturation detecting algorithm. The CT saturation detecting algorithm uses difference of secondary current of CT and detects CT saturation. The proposed method distinguishes percentage differential relay operation caused by faults from percentage differential relay operation caused by CT saturations.
키워드