The stability analysis of current mode controller considering feedback element

피드백 요소를 고려한 전류모드 제어기의 안정도해석

  • Published : 2001.10.26

Abstract

Recently the power supply equipments have tendency to take multiple feedback loop paths. In this paper, the state space averaging technique is applied for the analysis of flyback type current mode control circuit. We made real converter for the gurantee of stable output characteristic and proper design of feedback circuit. The validity of proposed method is verified from test results. The improvement of stability is confirmed by sinusoidal signal injection method with isolated transformer. It is known that phase margin is sufficient and gain crossover frequency $f_c$, is nearly 1/5 of switching frequency $f_s$, from the experimental result with frequency response analyzer.