Case Studies of Several Load Tests for Large Diameter Battered Steel Pipe Piles Constructed on the Offshore Area.

대구경 해상 강관말뚝의 설계지지력 확인을 위한 여러 가지 재하시험의 적용

  • 이정학 (대림산업㈜ 기술연구소) ;
  • 서덕동 (대림산업㈜ 기술연구소) ;
  • 정헌주 (대림산업㈜ 기술연구소)
  • Published : 2001.03.01

Abstract

It is very difficult to accomplish load tests of piles with large diameter constructed on the offshore area, because of requirement for large scaled loading equipment and bad testing conditions. Therefore, so far in many cases pile driving dynamic formulas have applied to quality control, and recently dynamic load test method is widely used for confirming bearing capacities of such piles. However, in cases of piles with very large diameter about 2,500mm, it is nearly impossible for regular type load test methods of piles such as static and dynamic to apply owing to very large design load. This is case studies of load tests such as modified static and dynamic load tests of piles and point load tests of rock samples for estimating rational allowable bearing capacity of very large diameter piles constructed on the marine area.

Keywords