Application of Curing Method Using the Heating Cable for Cold Weather Concreting

매입형 열선에 의한 한중콘크리트의 보양방법 적용에 관한 연구

  • Published : 2001.05.01

Abstract

The purpose of this study is to analyze the curing effect of heating cable for concreting in cold weather. An experiment was conducted to evaluate the temperature history of concrete structures cured with embedded heating cables. Results are as follows : In comparison with the non-heating case, applying of heating cable resulted in the rise of temperature in the range of $10^{\circ}C$. In order to get successful results, the optimal pitch length for the embedded heating cables ranged from 20cm to 25cm. When working with the existing curing methods, applying this heating cable would be more effective in concrete curing. Finally, a formula and process was suggested to predict the Internal temperature history of concrete structures under the various curing conditions.

Keywords