Fracture Behavior of CIP Anchor in Cracked Concrete

균열 콘크리트 면에서의 CIP앵커의 파괴거동

  • 김호섭 (고려대학교 토목환경공학과) ;
  • 윤영수 (고려대학교 토목환경공학과) ;
  • 윤영수 (한국원자력안전기술원) ;
  • 박성균 (브이에스엘 코리아(주))
  • Published : 2001.05.01

Abstract

This study concerns crack effect on concrete anchor system and prediction of tensile capacity, as governed by concrete cone failure, of single anchors located at center of concrete specimen. To Investigate crack effect three different types of crack such as crack width of 0.2mm and 0.5nm, crack depth of loom and 20cm, and crack location of center and biased point were simulated. The static tensile load was subjected to 7/8 in. CIP anchor embedded in concrete of strength 280kg/$cm^{2}$. Tested pullout capacity was compared to prediction value by each current design method (such as ACI 349-97, ACI 349 revision and CEB-FIP which is based on CC Method), In these comparison CC Method and ACI revision showed almost same value in uncracked concrete specimen, however in cracked concrete CC Method showed conservativeness. Therefore the design by ACI 349 revision is recommended for the safe and economic design.

Keywords