1/12 축소 철근콘크리트 상부벽식-하부골조 건축물의 진동대 실험

Shaking Table Tests of 1/12-Sale R.C. Bearing-Wall system with Bottom Piloti Frames

  • 이한선 (고려대학교 건축공학과 부교수, 정회원) ;
  • 고동우 (고려대학교 건축공학과 박사과정 학생회원) ;
  • 권기현 (서울시립대학교 건축공학과) ;
  • 김병현 (한국기계연구원 책임연구원)
  • 발행 : 2001.09.01

초록

The severe shortage of the available sites in the highly developed downtown area in Korea necessitates the construction of high-rise buildings which meet the need of residence and commercial activity simultaneously. The objective of this study is to investigate the seismic performance of this type of building structures. For this purpose, two 1 :12 scale 17-story reinforced concrete model structures were constructed according to the similitude law, in which the upper 15 stories have a bearing-wall system while the lower 2-story frames have two different layouts of the plan The one is a moment-resisting frame system and the other is a moment-resisting frame system with a infilled shear wall. Then, this model was subjected to a series of earthquake excitations. The test results show that the existence of shear wall reduced the shear deformation at the piloti frame, but has almost the negligible effect on the reduction of the overturning-moment angle.

키워드