전원전압과 DC-link 전압 추정에 의한 3상 컨버터 센서리스 제어

Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage

  • 발행 : 2001.07.01

초록

A new control method of three phase converter without measuring input Phase-voltage and DC-link voltage is Proposed. Input Phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In additon, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

키워드