Force Test of the Linear Induction Motor for Magnetic Levitation Train

자기부상열차용 유도형 리니어 모터의 작용력 시험

  • Published : 2001.07.18

Abstract

In this paper, the force test of arch-type LIM is treated. The method of direct measurement is used load-cell on 3-component force guage. Indirect method is used search coil on LIM. PC-based data aquistion system include two method and measure the force in driving state. Measured data of direct and indirect method are analyzed and compared.

Keywords