Proceedings of the KSME Conference (대한기계학회:학술대회논문집)
- 2000.04b
- /
- Pages.574-579
- /
- 2000
Off-design Performance Prediction of Centrifugal Pumps by Using TEIS model and Two-zone model
TEIS 모델과 두 영역 모델을 이용한 원심 펌프의 탈 설계 성능 예측
Abstract
In this study. an off-design performance prediction program for centrifugal pumps is developed. To estimate the losses in an impeller flow passage, two-zone model and two-element in series(TEIS) model are used. At impeller exit. the mixing process occurs with an increase in entropy. In two-zone model. there are both primary zone and secondary zone for an isentropic core flow and an average of all non-isentropic streamtubes respectively. The level of the core flow diffusion in an impeller was calculated by using TEIS model. While internal losses in an impeller an automatically estimated by using the above models, some empirical correlations far estimating external losses. far example, disk friction loss, recirculation loss and leakage loss are used. In order to analyze the vaneless diffuser flow. the momentum equations for the radial and tangential directions are used and solved together with continuity and energy equations.
Keywords