대한기계학회:학술대회논문집 (Proceedings of the KSME Conference)
- 대한기계학회 2000년도 춘계학술대회논문집B
- /
- Pages.65-70
- /
- 2000
한 측에서만 거칠기가 설치된 삼각덕트의 열전달과 압력강하 특성
Heat Transfer and Pressure Drop Characteristics of Triangular Ducts with One Side Rib-Roughened
초록
Experimental investigations were conducted to study the forced convection of fully-developed turbulent f)on· in horizontal equilateral duct fabricated with the same length and equivalent diameter, but different surface roughness Pitch ratio(P/e) of 4, 8 and 16 on the one side wall only The experiments were performed with the hydraulic diameter based Reynolds number ranged from 70.000 to 10,000 The entire bottom wall of the duct was heated uniformly and the other surfaces were thermally insulated. To understand the mechanisms of the heat transfer enhancement. measurements of the heat transfer were done to investigate the contributive factor of heat transfer promotion. namely the fin effect. And the results were compared with those of Previous investigations for similarly configured channels, at which they were roughened by regularly spaced transverse ribs in the rectangular and circular channels.
키워드