Fretting Oamage Evaluation of Zircaloy-Inconel Contact

지르칼로이-인코넬 접촉에서의 프레팅 손상 평가

  • 김태형 (경북대학교 기계공학과 대학원) ;
  • 김석삼 (경북대학교 기계공학부)
  • Published : 2000.06.01

Abstract

The fretting damage of the contact between Zircaloy-4 and Inconel 600 have Investigated. A fretting wear tester was designed to be suitable for this fretting test. In this study, the number of cycles, slip amplitude and normal load were selected as main factors of fretting wear. As the result of this research the wear volume increased with the increase of loads, slip amplitudes and the number of cycles and was more affected by slip amplitudes rather than by load. According to SEM, stick, partial slip, gross slip were observed on the surface of both specimens and wavy worn surfaces as the typical fretting damage were also Investigated due to accumulation of plastic flow.

Keywords