Tension Stiffening and Bond Length of Reinforced Concrete Members Subjected to Uniaxial Tension

1축 인장 부재의 인장강성 및 부착길이 효과

  • 조능호 (동아건설산업(주) 기술연구원) ;
  • 정원기 (동아건설산업(주) 기술연구원 수석연구원) ;
  • 강희철 (동아건설산업(주) 기술연구원) ;
  • 서정문 (한국원자력연구소 책임연구원) ;
  • 전영선 (한국원자력연구소 책임연구원)
  • Published : 2000.10.01

Abstract

Tension stiffening effects of reinforced concrete member with large diameter bar, mainly used at reactor building of nuclear power plant, are studied by uniaxial structural tests. Bond length and stress of steel bar, size of steel bar, and compressive strength of concrete are evaluated to tension stiffening by uniaxial tests. Problems and solution during the uniaxial test are suggested. The prevent splitting cracks, concrete cover-to-bar diameter ratio $c/d_{b}$ is kept 2.6~2.8. Because the bond length is increased as the size of steel bar, the specimen length of the D35 steel bar is required at least 2.0 m. The specimen length must be decided with bond length as well as concrete cover-to-bar diameter ratio to prevent splitting crack.

Keywords