Thermal Shield for Cryostat of KSTAR TOKAMAK
KSTAR CRYOSTAT의 열차폐막 설계
Abstract
KSTAR coils use super-conducting magnet systems. These coils operate around 4.5K and therefore require a thermal shield to reduce the heat load from outer cryostat. 80K thermal shields must be cooled by a forced flow of He gas at 20 bars without the pressure drop of 0.45 bar. Designed thermal shield shows that the pressure drop is lower than that of 0.5 bar.
Keywords