철골볼트 접합부 존재응력설계와 부재내력설계의 비교 연구

A Comparative Study on Design by Actual Stress and Design by Member Strength in Bolt Connections

  • 이만승 (포스코개발(주)설계본부)
  • 발행 : 1999.04.01

초록

There are two methods commonly used in design of splice plate connection of frame structure. The one is Design by Actual Stress which can sufficiently transfer actual force to an adjacent member using rows of bolts. The other is Design by Member Strength which is able to transfer total allowable stress of effective section area to a connected member. In real design, as a matter of convenience, Standard Connection Drawings have used according to Design by Member Strength. But this method underestimate connection force in shear connection where large connection moment occured. In this study, these Design methods are compared by connection moment in shear connections. and the adequate use of them are recommended. Also In order to evaluate more accurately the actual stress of splice plate of flange on moment. connection, a new calculation method of it is recommended.

키워드