Proceedings of the KIPE Conference (전력전자학회:학술대회논문집)
- 1999.07a
- /
- Pages.338-341
- /
- 1999
Harmonic Current Reference Generation of Single-Phase Active Filter for the Converter-Fed Locomotives
고속전철용 단상능동필터의 기준고조파전류 발생 방법
- Sung, Gi-Seok (Korea Univ.) ;
- Song, Joong-Ho (KIST) ;
- Choi, Ik (KIST) ;
- Choi, Ju-Yeop (KIST) ;
- Kim, Gwang-Bae (KIST) ;
- Kim, Kwon-Ho (KIST) ;
- Lim, Myo-Taek (Korea Univ.)
- 성기석 (고려대학교) ;
- 송중호 (한국과학기술원) ;
- 최익 (한국과학기술원) ;
- 최주엽 (한국과학기술원) ;
- 김광배 (한국과학기술원) ;
- 김권호 (한국과학기술원) ;
- 임묘택 (고려대학교)
- Published : 1999.07.01
Abstract
PWM controlled line-side converters of modern ac traction locomotives inject harmonic currents into the feeding overhead line. This causes problem of electromagnetic interference. Passive and Active filters are usually provided for a reduction of the line harmonics. Active filters are more reasonable than passive filters in terms of weight and space of the filters. Successful control of active filters requires an accurate harmonic current reference. A technique to generate the harmonic current reference is proposed in this paper. The analysis is performed in frequency domain and its effectiveness is verified by simulation.