A Study for Fast Light-Off of a Catalyst During Cold Start

냉시동시 촉매의 예열시간 단축에 관한 연구

  • Cho, Y.S. (Kookmin Univ., Dept. of Automotive Engineering) ;
  • Lee, Y.S. (Kookmin Univ., Dept. of Automotive Engineering)
  • 조용석 (국민대학교 자동차공학과) ;
  • 이윤석 (국민대학교 자동차공학과)
  • Published : 1998.10.09

Abstract

In order to meet the stringent emission regulations, fast light-off of a catalyst is essential to reduce the HC and CO emissions during cold start. Cranking Exhaust Gas Ignition (CEGI) method developed in this study showed that the catalyst reaches the light-off temperature in a few seconds after cold start. The CEGI system cuts off the ignition signal for a few seconds during the cranking period. so the unburned fuel-air mixture bypasses the combustion chamber and flows through the exhaust manifold. When the unburned mixture reaches two glow plugs installed upstream of the catalyst, it burns and releases the thermal energy to heat up the catalyst. Results from the FTP-75 tests showed that the exhaust emissions with the CEGI reduced by 47.7% for THC and by 88.6% for CO in the cold-transient phase of the test.

Keywords