NO Oxidation using Non-Thermal Plasma and NOx removal by NaOH-Water Solution Shower

비열플라즈마에 의한 NO의 산화와 NaOH 샤워해 의한 NOx의 제거특성

  • 박재윤 (경남대학교 전기공학과) ;
  • 고용술 (경남대학교 전기공학과) ;
  • 김익균 (경남대학교 전기공학과) ;
  • 박상현 (경남대학교 전기공학과) ;
  • 고희석 (경남대학교 전기공학과) ;
  • 이덕출 (인하대학교 전기공학과)
  • Published : 1998.11.28

Abstract

In this paper, the NO was oxidized $NO_2$ by using the non-thermal plasma and NOx removal characteristics were measured by showering NaOH water-solution to $NO_2$. The NO oxidation increased in the order of DC, AC, and Pulse. NOx oxidation for two stage with applied voltage was better than that for one stage with applied voltage. NO oxidation didn't depend on applied voltage. While NO oxidation was going on, NOx removal efficiency was 20-25%, however, significantly depended on the injection method of air and $H_2O$ + air. When NaOH water-solution density of 20% was showered to flue gases, NOx removal efficiency increased to 64%.

Keywords