Proceedings of the Korean Nuclear Society Conference (한국원자력학회:학술대회논문집)
- 1998.05a
- /
- Pages.899-905
- /
- 1998
Priority Rankings of the System Modifications to Reduce Core Damage Frequency of Wolsong NPP Units 2/3/4
- Kwon, Jong-Jooh (Korea Electric Power Research Institute nuclear Power Generation Laboratory) ;
- Kim, Myung-Ki (Korea Electric Power Research Institute nuclear Power Generation Laboratory) ;
- Seo, Mi-Ro (Korea Electric Power Research Institute nuclear Power Generation Laboratory) ;
- Hong, Sung-Yull (Korea Electric Power Research Institute nuclear Power Generation Laboratory)
- Published : 1998.05.01
Abstract
The analysis priority makings the recommendation to reduce the total core damage frequency (CDF) of Wolsong nuclear Power Plant nits 2/3/4 was Performed in this paper. In order to derive the recommendation, the sensitivity analysis of CDF on which major contributors effect m performed based on the accident quantification results during Level 1 Probabilistic safety assessment (PSA). Priorities were ranked in tile way that compares the CDF reduction rate with efforts required to implement those recommendations using risk matrix
Keywords