Development of Modified Product Consistency Test

  • Published : 1998.05.01

Abstract

Modified product Consistency Test (M-PCT) has been developed as an alternative to other existing methods in determining the leachability of glass. M-PCT, the leaching method, is a hybrid of MCC-l and PCT, but can provide quicker sample preparation. Larger diameter glass sample (1.0-2.0 mm) than in the PCT method can be used so that the glass beads are more easily produced and cleaned. From the M-PCT, the total mass loss (ML) of glass, the normalized elemental release rate (NLi), pH value of leachate have been obtained. For some selected glasses in which leaching rates have been known, their chemical durablility have been tested using the M-PCT method. The results are compared to the literature data for the glasses. It is found that M-PCT method is reasonable and suitable in determining the leachability of Low and Intermediate level Radioactive Waste glass form, such as the pH, elemental loss and total mass loss.

Keywords