도금폐수중의 유해물질 (중금속 및 시안) 처리를 위한 제철폐기물의 효율적 이용 방법 (II)

An Effective Method to Remove Toxic Material in Metal Plating Wastewater by Steel Mill Wastes (II)

  • 발행 : 1998.11.01

초록

This study was carried out to investigate the efficiency of steel mill slag and sludge in removing heavy metals and cyanide in metal plating wastewater. Laboratory experiments were peformed with jar tester, The tests were peformed at ambient temperature. The results of tests showed that overall rates metals removed were greater than 90 %. Metals were removed from solution as the combined effects of adsorption and precipitation in alkaline condition. The removal efficiency of cyanide by steel mill wastes was above 90 % at optimum conditions. In view of the test results and other engineering characteristics of steel mill slag and sludge, these industrial by-products from steel industry have a high potential to be used in metal plating wastewater treament and were particularly beneficial.

키워드