Design Criteria of the Auxiliary Resonant Snubber Inverter Using a Load-Side Circuit for Electric Propulsion Drives

  • Song, Byeong-Mun (Center Power Electronics Systems(CPES) The Bradley Department of Electrical Engineering Virginia Polytechnic Institute and State University) ;
  • Jih-Sheng(Jason) Lai (Center Power Electronics Systems(CPES) The Bradley Department of Electrical Engineering Virginia Polytechnic Institute and State University) ;
  • Kwon, Soon-Kurl (Dept. of Electrical Engineering Kyungnam University)
  • Published : 1998.10.01

Abstract

The Design criteria of the auxiliary resonant snubber inverter (ARSI) using a load-side circuit are discussed in relation to electric propulsion drives. In this regard, this paper attempts to develop a set of design criteria for the ARSI. First, the switching characteristics of IGBTs under soft-switching mainly in terms of dv/dt/, di/dt and switching losses are discussed and utilized for optimizing the selection of the resonant components in the system. After that, the proper control strategies of ARSIs are analyzed and simulated based on voltage space vector modulations. Later, the design, control and implementation of the auxiliary resonant circuit suitable for industrial products are analyzed and presented. And finally, other factors including power stage layout, packaging and the choice of current sensors are included. The detailed simulation and experimental results will be included based on a laboratory prototype. The proposed design criteria of the ARSI would help the implementation of an electric propulsion drive system.

Keywords