Proceedings of the Korean Nuclear Society Conference (한국원자력학회:학술대회논문집)
- 1997.05a
- /
- Pages.213-218
- /
- 1997
RTD Bypass Line Elimination at Kori Nuclear Power Plant 3&4
- Yoon, Duk-Joo (Korea Electric Power Research Institute(KEPRI)) ;
- Lee, Chang-Sup (Korea Electric Power Research Institute(KEPRI)) ;
- Jun, Hwang-Yong (Korea Electric Power Research Institute(KEPRI)) ;
- Lee, Jae-Yong (Korea Electric Power Research Institute(KEPRI)) ;
- Song, Dong-Soo (Korea Electric Power Research Institute(KEPRI))
- Published : 1997.05.01
Abstract
The RTD Bypass Loops at Kori Unit 3&4 will be removed and a new system will be designed and will be installed to replace it. The replacement system provides equal or better performance and eliminates some Persistent problems. The Resistance Temperature Detector (RTD) bypass line is eliminated to reduce the radiation exposure to operators and workers. After the elimination, the resistance temperature detectors are installed in scoop of the reactor coolant piping to detect a representative temperature. This study includes safety evaluation, RTD response time Analysis, Uncertainty Analysis, LOCA evaluation and Structural Analysis.
Keywords