Detachment of Vane Tip in a Positive Displacement Vane Pump

베인 이간 현상에 관한 연구

  • Published : 1997.04.01

Abstract

This paper reports on the theoretical study of the vane motions in a positive displacement vane pump. Vane detachment cause the pressure fluctuation, noise, wear in cam ring, and decrease the volumetric efficiency. Dynamic equation of vane motion and flow continuity equation have been modeled and solved simultaneously using 4th order Runge-Kutta method. As results of analysis, vane detachment occurs due to pressure overshoot by excess compression in the pumping chamber. Amount of vane detachment has been reduced by decreasing the pressure overshoot.

Keywords