ANALYSIS AND DESIGN OF MAT FOUNDATION FOR HIGH-RISE BUILDINGS

초고층 건물의 전면기초(MAT기초) 해석 및 설계

  • Published : 1994.09.01

Abstract

Types of foundation of high rise buildings are primarily determined by loads transmitted from super structure, soil bearing capacity and available construction technology. The usd of deep foundation cannot be justified due to the fact that rock of enough bearing capacity is not found down until 90 ~ 100m. When a concentration of high soil pressure must be distributed over the entire building area, when small soft soil areas must be bridged, and when compressible strata are located at a shallow depth, mat foundation may be useful in order to have settlement and differential settlement of variable soils be minimized. The concept of mat foundation will also demonstrate some difficulities of applications if the load bearing demand directly carried down to the load -bearing strata exceeds the load -bearing capacity. This paper introduces both the analysis and design of mat type foundation for high rise buildings as well as the methodology of modelling of the soil foundation, especially, engineered to redistribute the stress exceeding the soil bearing capadity. This process will result in the wid spread of stresses over the entire building foundation.

Keywords