Location Effect of Tuned Mass Dampers on the Response of Buildings
TMD의 위치변화에 따른 건물의 응답효과
- Min, Kyung-Won ;
- Hong, Sung-Mok ;
- Hwang, Jae-Seung
- Published : 1993.04.01
Abstract
Conventional tuned mass dampers are located on the top floor of tall buildings, which reduce the fundamental mode response of buildings. Higher modes may have a greater contribution toward the acceleration response of tall buildings. To reduce this, additional tuned mass dampers are required and could be substituted as building equipments. This paper shows, with a numerical ezample, how the lecate tuned mass damper in order to reduce the higher mode response effectively