A study on advanced control of electrolyzer process
전해조 공정의 고급제어에 관한 연구
Abstract
This paper presents a merit of feedforward Dyamic Matrix Control(DMC) for electrolyzer process. The electrolyzer consists of anode part and cathode part that are separated by ion membrane. As the electolyzer process consumes a large amount of electricity, electric power change is inevitable in order to take advantage of the cheaper electricity during night. But the electric power change makes the electrolyzer control difficult because the electric power change affect the dynamics of the process. Feedforward DMC treats the electric power change as a load disturbance and gives the weighting value to the disturbance prediction part in the DMC algorithm. Feedforward DC shows better regulation performance than PID control and feedforward-feedback control for electrolyzer process.
Keywords