Loss Cut of Air-Cooled Waterwheel Generator with AC Variatle Speed Drive for Cooling Fan Motor(s)
교류 가변속 장치의 냉각팬 적용에 의한 수력 발전기 손실 저감
- Hur, Sung-Kwang (A & C Research Center KEPCO.) ;
- Rhew, Hong-Woo (A & C Research Center KEPCO.) ;
- Park, Min-Ho (Dept. of Elect. Eng. Seoul Nat'l Unv.)
- Published : 1989.07.21
Abstract
The air-cooled waterwheel generator has a fan connected to waterwheel shaft or motor driven fan or fans. The fans are operated at constant speed, constant input, regardless of generator loss which is varied according to generator output and coolant the perature. Energy savings may he possible if the cooling air flow is controlled according to generato output and air temperature depending on season. The simulation and experience have been done on the 22.6 KVA Waterwheel generator by using AC variable speed drive. The results gave us los cut of generator.
Keywords