추종 오차를 최소화하는 극-영점 배치 자기 동조 제어기
Pole-zero placement self-tuning controller minimizing tracking error
초록
In this paper, a self-tuning controller design is proposed by using pole-zero placement method and considering a system time delay. To got better tracking for the generalized self-tuning controller, pole placement method for the closed loop system and zero placement method for the error transfer function are Introduced. The proposed method shows better efficiency than pole placement method for minimizing tracking error. Simulation gives good results in tie reference signal tracking.
키워드