Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

Analysis of the acceleration of KHST prototype on the high speed test line (한국형 고속전철의 진동가속도 시험 연구)

  • Park Chankyounn;Kim Youngguk;Kim Seogwon
    • Proceedings of the KSR Conference
    • /
    • /
    • pp.567-573
    • /
    • 2003
  • Korean High Speed Train (KHST) has been tested on high speed line in JungBu site since it was developed in 2002. The data acquisition system was developed to accomplish successfully this on-line test for proving the dynamic Performance of KHST. This system was consist of the personal computers based on National Instrument PXI modules and the test programs based on Labview 6i. This paper shows that this system is efficient to acquire the test data through the multi-channels connected the accelerometers which located in long distance places and flexible to change and add channels for data acquisition. The dynamic analysis of an on-line test is very complicate because the environmental conditions, as examples radius of curve, inclination of the track, tunnels, bridges, and so forth, and running conditions, as examples driving, braking, the number of working motors, and so forth, have an effect on the results. Therefor, the analysis method is important and this paper proposes the efficient procedure graphically, showing the proposed method simplify the accelerations of 5th bogie frame acquired during the on-line test for KHST.

  • PDF

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Han, Dong-Hee;Lee, Un-Yong;Lim, Kee-Joe;Choi, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • /
    • pp.1121-1124
    • /
    • 2004
  • Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. The diagnosis methods in off-line most are the method for virgin and last aged sample. However, the diagnosis method in on-line is method that can be evaluate sample state as progressing continuously aging test in beginning, The diagnosis method in on-line is arranged as following: leakage current measurement, electric field, surface state investigation, thermal image, emitting light measurement and then so. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination.

  • PDF

On-line and Off-line Partial Discharge Monitoring System with HVAC Testing (HVAC에 의한 On-line, Off-line PD 모니터링)

  • Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

Status of Occupational Therapists on Unilateral Neglect Test Tools Usage and Symptom Classification

  • Jang, Woo-Hyuk
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.5
    • /
    • pp.271-275
    • /
    • 2017
  • Purpose: The aim of this study was to investigate the current status of the use of neglect test tools and the awareness for egocentric neglect (EN) and allocentric neglect (AN). Methods: A survey questionnaire was distributed to occupational therapists attending continuing education at the Daegu-Gyeongbuk branch on April 16. A total 143 responses were collected, and with the exception of 5 incomplete responses, 138 of them were analyzed. Results: The most commonly used unilateral neglect test tools were the line bisection test (86 responses, 62.3%), cancellation test (35 responses, 25.4%), copy and drawing test (7 responses, 5.1%). In a follow-up survey of 86 respondents who used line bisection tests as the most commonly used test, the majority (82 responses, 95.3%2) were found to use the 20-line test paper. In question about the familiarity and education experience for test manual, only 20 responses (23.2%) and 3 responses (3.5%) answered 'Yes'. In a question about the experience of a manual and the article for the manual, 25 responses (29.1%) answered 'Yes'. In the question regarding the separation of EN and AN on the unilateral neglect test, 44 responses (31.9%) were 'distinction' and 94 responses (68.1%) were 'no distinction'. Conclusion: Information on the guidance and interpretation of the line bisection test is lacking and the concept of EN and AN was insufficient.

Management and operation of K-AGT test line (한국형경량전철 시험선의 관리 및 운영)

  • Han, Seok-Youn;Jun, Bong-Roong;Lee, Ho-Yong;Lee, An-Ho
    • Proceedings of the KSR Conference
    • /
    • /
    • pp.964-967
    • /
    • 2006
  • Korea Railroad Research Institute (the following 'KRRI') built AGT test line in Gyeong San-city, Kyongsang-bukdo province, Korea on August, 2004. This test line is exclusively used for the test of the driverless rubber-tired AGT system, and applied with research result of AGT System Development Project like vehicles, power supply, control and signaling, track and infrastructure system. The test line is available for the test of rubber tired AGT system's performance, function, safety. In this paper, we described the operation system of test line for the test of performance, safety, reliability, and also system operation in emergency. Finally we present the operation result of test line.

  • PDF

On-line Bus Monitoring of a System Using Bondary-Scan (경계스캔 구조를 사용한 시스템의 온라인 버스 모니터링)

  • Song, Dong-Sup;Bae, Sang-Min;Kang, Sung-Ho;Park, Young-Ho
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.12
    • /
    • pp.675-682
    • /
    • 2000
  • When a system is composed of multi-boards, an efficient bus arbitration method for the data transfer bus must be provided for guaranteeing proper operations. In this paper, a new test methodology is developed which is used for testing on-line bus arbitration. In the new test methodology, events that are occurred during bus arbitration are defined, and expected signals during fault-free bus arbitration are compared with the signals captured during on-line bus arbitration using boundary-scan cells. For this, a new test architecture is proposed which is efficient for the maintenance and the repair of multi-board systems. In addition, the new methodology can be used with off-line interconnect test using boundary-scan.

  • PDF

A New Test Algorithm for Bit-Line Sensitive Faults in High-Density Memories (고집적 메모리에서 BLSFs(Bit-Line Sensitive Faults)를 위한 새로운 테스트 알고리즘)

  • Kang, Dong-Chual;Cho, Sang-Bock
    • Journal of IKEEE
    • /
    • v.5 no.1
    • /
    • pp.43-51
    • /
    • 2001
  • As the density of memories increases, unwanted interference between cells and coupling noise between bit-lines are increased. And testing high-density memories for a high degree of fault coverage can require either a relatively large number of test vectors or a significant amount of additional test circuitry. So far, conventional test algorithms have focused on faults between neighborhood cells, not neighborhood bit-lines. In this paper, a new test algorithm for neighborhood bit-line sensitive faults (NBLSFs) based on the NPSFs(Neighborhood Pattern Sensitive Faults) is proposed. And the proposed algorithm does not require any additional circuit. Instead of the conventional five-cell or nine-cell physical neighborhood layouts to test memory cells, a three-cell layout which is minimum size for NBLSFs detection is used. Furthermore, to consider faults by maximum coupling noise by neighborhood bit-lines, we added refresh operation after write operation in the test procedure(i.e.,$write{\rightarrow}\;refresh{\rightarrow}\;read$). Also, we show that the proposed algorithm can detect stuck-at faults, transition faults, coupling faults, conventional pattern sensitive faults, and neighborhood bit-line sensitive faults.

  • PDF

Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings (13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석)

  • Chang, Jeong-Ho;Lee, Dong-Keun;Lee, Heung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.11
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

The Comparison of Fabric Images between On-line and Off-line by Fabric Types and Characteristics (직물의 종류와 특성에 따른 온라인과 오프라인에서의 의복소재 이미지 비교)

  • Kim, Hee-Sook;Cho, Shin-Hyun
    • Korean Journal of Human Ecology
    • /
    • v.13 no.5
    • /
    • pp.787-798
    • /
    • 2004
  • This research was designed to compare clothing fabric images between on- and off-line by fabric types and its characteristics. 125 subjects who have a fashion design major evaluated the fabric image of various 16 kinds of specimens on- and off-line. Frequency, x2-test, t-test, and Pearson correlation were used for statistical analysis by SPSS WIN 11.0. The results of this study are as follows: 1. The advantage of on-line shopping includes low price and purchasing convenience, etc. On-line shoppers mostly purchase clothing items, such as T-shirt and slacks. In most cases, texture of fabrics provides a main cause for the shoppers' discontentment with internet shopping. 2. The results of t-test for the difference of the evaluation score show that plain or pile weave and highly thick or thin fabrics-for example, Organdy, Corduroy, Nylon Taffeta, Plush, etc.-have a large difference between on-and off-line image. On the other hand, medium-thick twill weave-for example, Tweed, Flannel, etc.-or patterned weave-Chiffon, Dobby fabric, etc.-shows a small difference. 3. The results of correlation of the evaluation score indicate that wool twill fabrics like Tweed, Saxony, and Polafleece show a high correlation between two kinds of evaluation score. In texture preference, no correlation exists between on-line and off-line. 4. With an analysis on fabric image evaluation by fabric characteristics, smooth, shiny pink Satin was found the most positively-evaluated item in all evaluation fields except in pattern preference and individuality. On the other hand, thick olive green Corduroy was evaluated most negatively in the fields of elegance, luxury, and feminine. 5. When compared with real ones, thin fabrics provide a different on-line fabric image. For example, Nylon Taffeta and Organdy were evaluated positively on-line because of luster and pastel tone color. However, lusterless uneven cotton Seersucker was evaluated negatively. 6. Real fabrics preference is more negative than on-line ones. In addition, patterned or unique fabrics display a high agreement between the two kinds of images.

  • PDF