Search Result 91, Processing Time 0.036 seconds

A Study on the Characteristics of Convective Activities related to Atmospheric Stability Index and Thunderstorms over the Naro Space Center (나로우주센터 상공의 대기 안정도지수 및 뇌운관련 대류활동 특성 연구)

  • Kim, Hong-Il;Choi, Eun-Ho;Seo, Seong-Gyu
    • Journal of Environmental Science International
    • /
    • v.28 no.12
    • /
    • pp.1133-1145
    • /
    • 2019
  • Successful launch requires state-of-the-art launch vehicle technology and constant test operations, However, the meteorological threat to the launch vehicle flight trajectory is also an important factor for launch success. Atmospheric stability above the Naro Space Center at the this time is very important, especially because the initial flight operation can determine the success of the launch. Moreover, during the flight of launch vehicle with rapid pressure and thrust into the atmosphere, convection activity in the atmosphere may create environmental conditions that cause severe weather threats such as thunderstorms. Hence, studies of atmospheric instability characteristics over the Naro Space Center are a necessary part of successful launch missions. Therefore, the main aims of this study were to (1) verify the atmospheric stability index and convection activity characteristics over the Naro Space Center using radiosonde data observed from 2007 to 2018 by the Naro Space Center, (2) analyze changes in the atmospheric stability index according to monthly and seasonal changes, and (3) assess how the calculated atmospheric stability index is related to actual thunderstorm occurrence using statistical analysis. Additionally, we aimed to investigate the atmospheric characteristics above the Naro Space Center through the distribution chart of the atmospheric stability index during summer, when convection activity is highest. Finally, we assessed the relationship between lightning occurrence and unstable atmospheric conditions, through predictability analysis performed using the lightning observation data of the Korea Meteorological Administration.

A Study On The Configuration Of UHD High Speed Digital Camera System In the Naro Space Center (나로우주센터 초고화질(UHD) 고속 디지털카메라 시스템에 대한 구성방안 연구)

  • Park, Doo-Jin;Noh, Young-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • /
    • pp.536-538
    • /
    • 2017
  • UHD high speed digital camera system will be installed around launch pad and launch complex tower to acquire high speed image for motion analysis of integral parts of launch vehicle during the lift-off of KSLV-II in the Naro space center. In this paper, We compared configuration of high speed digital camera system operating in the Naro space center with UHD high speed digital camera system for mission of KSLV-II.

  • PDF

Numerical Simulations of Local Wind Field at the Naro Space Center by MUKLIMO with Terrain and Surface Effects (지형과 지표효과를 고려한 나로 우주센터의 국지규모 바람장 수치모의)

  • Yoon, Ji-Won;Min, Kyung-Duk
    • Journal of the Korean earth science society
    • /
    • v.25 no.8
    • /
    • pp.784-798
    • /
    • 2004
  • Microscale wind fields were simulated by MUKLIMO at the Naro Space Center, where complicated mountainous terrain and trees exist. In order to test the model's sensitivity with the effects of terrain and trees, experimental simulations were conducted under the various initial conditions. The experiments showed that the effects of trees were more significant on flat surfaces than on mountain cliffs. Based on the results, an actual 10 m level microscale wind field was simulated at the Naro Space Center, which has complicated mountainous terrain. Simulations of wind fields before and after the construction of the launching site were also conducted. It was found that MUKLIMO was of the mesoscale wind fields at the Naro Space Center.

Study on the random noise characteristic of the tracking radar in Naro space center (나로우주센터 추적레이더의 잡음 특성 분석)

  • Choi, Jee-Hwan;Shin, Han-Seop;Kim, Dae-Oh;Kim, Tae-Hyung
    • Aerospace Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.151-157
    • /
    • 2010
  • The tracking radars in NARO space center are precious, long-range tracking systems for tracking the launch vehicle (KSLV-1) and transmitting TSPI (Time, Space and Position Information) data to MCC (Mission Control Center). Because TSPI data from tracking radars to MCC are important information for the launch mission and flight safety control, TSPI data are required to be more accurate. In this paper, we analyzed theoretically the required specification of the random noise error in tracking radar and verified the real random noise error. In this analysis, we evaluated the TSPI data of several flight tests performed in NARO space center.

Analysis of Slant Range Accuracy Using The Transponder of Doppler Radar (도플러 레이다의 트랜스폰더를 이용한 사거리 정확도 분석)

  • Park, Doo-jin;Noh, Young-hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • /
    • pp.484-486
    • /
    • 2018
  • MF-CW(Multi-Frequency Continuous Wave)operated on Electro-Optical Tracking System to measure slant range of space launch vehicle and aircraft at Naro Space Center. In this paper, we compared and analyzed the difference exactly measured slant range using the laser lightwave range measuring equipment with measured on the transponder and described the accuracy of slant range.

  • PDF

A Study On The Doppler Radar Of Range Measurement On Electro-Optical Tracking System (광학추적장비의 거리측정 도플러 레이더에 관한 연구)

  • Park, Doo-Jin;Noh, Young-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • /
    • pp.700-702
    • /
    • 2016
  • The Doppler Radar that mounted on Electro Optical Tracking System has been operated to measure range and velocity during the initial mission of space launch vehicle at Naro space center. In this paper, we mentioned configuration of MFCW(Multi frequency Continuous Wave) and FMCW(Frequency Modulation Continuous Wave) Doppler Radar on Electro Optical Tracking System and described method of range measurement.

  • PDF

Development of Cryogenic Propellant Filling System for Launch Vehicle (발사체 극저온 추진제 충전시스템 개발)

  • Yu, Byung-Il;Kim, Ji-Hoon;Park, Pyun-Gu;Park, Soon-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • /
    • pp.676-677
    • /
    • 2010
  • In Naro Space Center, Naro launch vehicle launched 2 times. Launch pad for Naro launch vehicle in Naro space center equipped propellant feeding facility for operating launch process. This paper studied development process and operating method for liquid oxygen filling system of cryogenic propellant systems in launch pad propellant feeding facility.

  • PDF

Safety Management for KSLV-I, Naro (KSLV-I 나로호의 발사체 안전 관리)

  • Cho, Sang-Yeon;Shin, Myung-Ho;Oh, Seung-Hyup;Kim, Young-Mok
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.198-203
    • /
    • 2010
  • KSLV-I, a.k.a. Naro is the 1st Korean satellite launch vehicle, which was launched at Naro space center by Korea Aerospace Research Institute (KARI) in AUG. 2009, and JUN. 2010. Although the missions of 1st and 2nd launch of KSLV-I - inject the space craft into the designated orbit - were not successful, safety of launch vehicle was accomplished through the cooperation with the Russian partner Khrunichev Space Research and Production Center (KhSC). Both parties co-developed the safety management program to ensure launch safety. In this paper, the analysis and contents of safety program are illustrated.

Technical Trend of Time Synchronization Equipment in Naro Space Center (나로우주센터 표준시각 동기화장비 기술동향)

  • Han, Yoo-Soo;Choi, Yong-Tae
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.1
    • /
    • pp.116-123
    • /
    • 2008
  • In the launch mission, mission control systems and tracking systems need time synchronization for data monitoring and data analysis. There are several standards for time synchronization and an adequate standard is selected according to the requirement of time accuracy and cost among time synchronization standards. Oscillators are used to maintain time accuracy. There are some kinds of oscillators with diverse characteristics and an adequate oscillator can be adopted according to time accuracy. In this paper, we will specify characteristics of several oscillators and standards generally used for time synchronization. And we will also introduce TSDN(time synchronization and display network) for time synchronization in Naro Space Center.

  • PDF