건축물의 공조방식 선택과정에 있어서 질적 설계요소들의 디자인 결정방법에 관한 연구 (A Study on Design Decision of Qualitative Design Factors in Selecting of HVAC Type for Building)

  • 우세진
    • 설비공학논문집
    • /
    • v.16 no.8
    • /
    • pp.762-769
    • /
    • 2004
  • Not only in building design but also in HVAC system design, it is important to ensure an objectivity in schematic design. In the study, the author suggested a method to make a logical decision for quality design factors a(footing the selection of HVAC type in initial design process, and to provide objective design values. Fuzzy theory, one of the theories describing in quantitative way the ambiguous-natured linguistic values, was used to determine the qualitative design factors of linguistic parameter nature. It was found that it has a potential as a method to determine a HVAC type satisfying the required values of qualitative design factors involved in selection of the system type. But this needs further studies to be settled in the selecting of HVAC type.

에너지 절약적 공조시스템 선정을 위한 기초적 연구 (A Study on the Energy Conservational HVAC System Design Strategies)

  • 조진균;홍민호;정차수;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • /
    • pp.58-63
    • /
    • 2007
  • Lots of needs are being paid for how to design HVAC system in large-scale buildings. Increasing awareness of energy use is main point of this research. HVAC systems' energy characteristics are not clearly identified and understood, so the optimal design of HVAC system is very important. The energy parameters of HVAC design that are system input energy, water/air moving equipments (pumps/fans) energy and outdoor air conditioning energy for IAQ are important. The purpose of this study is to provide the basic data for energy conservational HVAC design strategies.

  • PDF

선박용 HVAC 시스템의 소음저감성능 평가 (Evaluation of Noise Reduction Performance of HVAC System for Ships)

  • 김상렬;김현실;김재승;김봉기;이성현
    • 한국음향학회지
    • /
    • v.29 no.8
    • /
    • pp.497-503
    • /
    • 2010
  • 본 논문은 여객선용 HVAC 시스템 목업을 구축하여 HVAC 요소의 성능평가를 수행한 결과를 다루었다. 측정은 룸 유니트 (Room Unit), 소음기 등 6가지 종류에 대해 이루어졌으며 여러 유량에 대해 삽입손실을 측정하였다. 소음기 직경이 작고 유량이 클수록 유동소음이 커져서 소음저감효과를 방해하지만, 직경이 커질수록 유동소음의 효과는 작아지고 삽입손실은 최대 25 dB까지 나타남을 확인하였다. 디퓨저 형태의 룸 유니트는 대체로 삽입손실이 0 - 10 dB 이지만 노즐 형태는 삽입손실이 최대 -15 dB 까지 소음이 커질 수 있음을 확인하였다. 또한 덕트 배열에 따라 최대 2 dB 까지 실내소음이 차이날 수 있음을 보였으며 각 룸 유니트에 동일한 유량이 배출하도록 조절하는 것이 보다 낮은 소음레벨을 얻을 수 있음을 확인하였다.

선박용 대형 덕트의 소음 특성 전산해석 연구 (Computational Analysis on the Noise Characteristics of Ship Large Duct)

  • 송지훈;홍석윤;이이수;권현웅
    • 해양환경안전학회지
    • /
    • v.21 no.6
    • /
    • pp.751-758
    • /
    • 2015
  • 공조시스템의 소음 예측은 주로 NEBB에서 제안한 경험적인 방법에 의해 수행된다. 그러나, NEBB에서 제안한 방법은 선박에만 있는 대형 덕트의 요소를 반영하지 못하므로 선박에 적용하는데 한계가 있다. 본 논문에서는 선박용 대형 덕트의 소음 예측을 위한 전산해석방법을 연구하였다. 경계요소법을 사용하여 대형 덕트의 단위 길이당 소음 감소량에 대한 추정식을 개발하였고, 경계요소법과 전산유체역학을 사용하여 보강재가 설치된 대형 덕트에서의 유동기인소음을 예측하였다. 유입 유속이 10m/s, 보강재의 종류가 200플랫 바인 경우 100 dB 이상의 큰 소음이 발생하는 것을 알 수 있었다. 또한, 경계요소법과 유한요소법을 사용하여 덕트 투과 소음을 예측하였다. 덕트 내부와 외부의 음압 값 차이는 대략 10~15 dB정도 인 것을 알 수 있었다. 이를 통해 조선소에서는 대형 덕트를 포함한 선박 HVAC 소음 예측을 할 수 있을 것으로 기대한다.

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of shipboard large-sized low-noise room unit with multiple outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회:학술대회논문집
    • /
    • /
    • pp.600-605
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlet. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

  • PDF

다수의 출구를 가진 선박용 대형 저소음 룸유닛 개발 (Development of Shipboard Large-sized Low-noise Room Unit with Multiple Outlets)

  • 김상렬;김현실;이성현;박근효
    • 한국소음진동공학회논문집
    • /
    • v.22 no.5
    • /
    • pp.468-473
    • /
    • 2012
  • In this paper, the acoustic performance of a shipboard large-sized room unit is studied. The room unit is a kind of rectangular absorptive chamber with a partition whose surface absorptive material with fabric skin is attached to. The room unit has one inlet and three outlets. At the inlet, a plane damper is installed to control the flow rate. The acoustic performance of a prototype room unit is measured using a HVAC mock-up. It is shown that its insertion loss is comparable with that of a commercially-used room unit but the developed room unit generates flow noise higher than the other one. The major source of flow noise is analyzed by NADS-R, the noise analysis program for room unit. Cone-shaped dampers are proposed to be used as the damper of a room unit to reduce flow noise. It is shown that the cone-shaped damper decrease flow noise remarkably.

자동차 전면유리 제상 메커니즘의 수치해석 연구 (A Numerical Study of a Vehicle Windshield Defrosting Mechanism)

  • 강승재;전용두;이금배
    • 에너지공학
    • /
    • v.19 no.3
    • /
    • pp.151-155
    • /
    • 2010
  • 자동차 전면유리를 통한 적당한 가시거리의 확보와 제상 시간은 주요 설계 요소들이다. 이런 요소들의 성능을 향상시키기 위해, HVAC 시스템에서 생성되는 유체의 흐름과 열전달 특성을 이해하는 것이 필요하다. 제상 노즐의 성능을 조사하기 위해 수치해석을 수행하였다. 본 연구에서는 현재 디자인의 모순과 제상 메커니즘의 개선방법을 보여주고 있다. 수치해석 결과 현재 부착된 제상 노즐로는 최대 공기흐름이 전면유리 하단부에서 최대 공기흐름이 나타나고 있으며, 이는 만족스럽지 못한 가시거리를 확보하게 된다. 제상 노즐의 분사 각도가 45도일때 탁월한 제상성능을 보여주고 있다. 수치해석 결과들은 NHTSA에서 정한 규정들을 만족시킨다.

HACCP의 환경 최적화를 위한 식품 클린룸 설계에 관한 연구 (A study on the food clean room system observing the regulations of HACCP)

  • 원영재;서기원
    • 대한설비공학회:학술대회논문집
    • /
    • /
    • pp.520-526
    • /
    • 2009
  • This study proposed the optimum design values for the biological clean room system observing the regulations of Hazard Analysis Critical Control Point (HACCP). Even though the standard for industrial clean room system has been well established, the basis for biological food clean room system is the first stage. In order to prevent the contaminations in advance for food storages, processes, and distributions, the criterion of Hazard Analysis Critical Control Point is positively required. This study also suggested the possible ways of how to avoid the hazardous contaminations.

  • PDF