• Title/Summary/Keyword: 손실

Search Result 15,012, Processing Time 0.147 seconds

Analysis of the Top Loss Coefficient for Flat Plate Collector in a Solar Air-Conditioning System during Winter (태양열 이용 냉난방 공조시스템중 평판형 집열기의 동계 상부 열손실 해석)

  • Kim, B.C.;Choi, K.H.;Kum, J.S.;Kim, J.R.
    • Solar Energy
    • /
    • v.18 no.3
    • /
    • pp.15-24
    • /
    • 1998
  • There are mainly 3 heat losses from solar collector; top, bottom, and edge heat loss. Usually edge heat loss is small so that could be neglected. Of the total thermal losses occurring in a flat plate solar collector, top loss heat losses are dominant. Therefore it is necessary to calculate the top loss coefficient accurately in order to find out performance of solar collector. The flat plate solar collector(regenerator in summer) used in this study was made for year-round all conditioning. In order to find out collector efficiency for heating in winter without a system change, outdoor experiment was done. The top loss coefficient of this collector was about 3 to $4.5W/m^2^{\circ}C$. Futhermore use of selective coating in trickling surface can improve a performance of flat plate solar collector.

  • PDF

Evaluations on the Characteristics of Pressure Drop f3r the Design of Intravascular Artificial Lung Assist Device (혈관 내 폐 보조장치 설계를 위한 압력손실 특성 평가)

  • 김기범;권대규;박재관;정경락;이삼철
    • Membrane Journal
    • /
    • v.13 no.1
    • /
    • pp.20-28
    • /
    • 2003
  • In this study, we try to formularize simultaneous equations to make a prediction about pressure drop for designing intravascular artificial lung assist device. Designing parameters to predict the effect of pressure drop and designed modules under various conditions were studied through an experimental modeling before inserting the artificial lung assist device into as venous. We measured pressure drop in various number of hollow fiber membranes, when the inside diameter of shell is fixed in 3 cm, and tried to develope the prediction equations by curve fitting based on the correlation between the experimental pressure drop and the device frontal area or packing density. The results showed that pressure drop increased with 2nd order functional formula as the liquid flow rate, the frontal area, and the packing density increased. Also, we can estimate the pressure drop as a function of the frontal area or packing density. The pressure drop obtained from the experiment was similar to that from the equation, confirming the usefulness of the equation.

A Study on the Heat Loss Improvement in a Refrigerator Ice Dispenser by Using Reverse Heat Loss Method (역열손실 방법을 이용한 냉장고 얼음 배출구 영역에서의 열손실 개선에 관한 연구)

  • Ha, Ji Soo
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.105-111
    • /
    • 2013
  • The present study has been carried out to reduce the heat loss from a built in refrigerator by using reverse heat loss method to discern the region with larger heat loss. To perform this purpose, an infrared thermographic camera has been used to measure the surface temperature of the refrigerator and tried to improve the heat loss near the ice dispenser. The numerical heat transfer analysis also has been accomplished to clarify the heat transfer mechanism near the ice dispenser. The possible applicable method to reduce heat loss was increasing the curvature radius at the ice dispenser corner. The curvature radius has been changed from 0mm to 40mm to see the effect of the curvature at the corner. From the present research, the optimal curvature radius for the reduction of heat loss at the ice dispenser could be 30mm.

Vibration-Based Monitoring of Prestress-Loss in PSC Girder Bridges (PSC 거더교의 진동기반 긴장력 손실 모니터링)

  • Kim, Jeong-Tae;Hong, Dong-Soo;Park, Jae-Hyung;Cho, Hyun-Man
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.21 no.1
    • /
    • pp.83-90
    • /
    • 2008
  • A vibration-based monitoring system is newly proposed to predict the loss of prestress forces in prestressed concrete (PSC) girder bridges. Firstly, a global damage alarming algorithm is newly proposed to monitor the occurrence of prestress-loss by using the change in frequency responses. Secondly, a prestress-loss prediction algorithm is selected to estimate the extent of prestress-loss by using the change in natural frequencies. Finally, the feasibility of the proposed system is experimentally evaluated on a scaled PSC girder model for which acceleration responses were measured for several damage scenarios of prestress-loss.

Allocation of Real Power losses to Individual Loads Under Competition of Deregulated Power Industries (전력산업의 경쟁체제에서 유효전력 손실을 부하에 배분하는 방법)

  • Ro, Kyoung-soo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.114-120
    • /
    • 2004
  • The paper proposes a method calculate the allocations of real power losses in transmission lines to individual loads based on loss distribution factors and compares them with those using marginal loss factors. The proposed method is implemented by defining loss distribution factors and analysing the individual loads' shares in the transmission line losses. Computer simulations on a 9-bus sample system verify effectiveness of the algorithm proposed and give an assertion that it is desirable to allocate power losses to loads using loss distribution factors rather than based on marginal loss factors.

Loss Characteristics of the 100m Gochang HTS-cable System (100m급 고창HTS-케이블시스템의 손실특성)

  • Li, Z.Y.;Ma, Y.H.;Jin, H.B.;Ryu, K.;Sohn, S.H.;Hwang, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.298_299
    • /
    • 2009
  • 전력분야 응용 중, 특히 교류손실측면에서 장점을 지니고 있는 HTS-케이블 및 HTS-한류기의 경우는 선진 세계 각 국에서 배전급 전력계통에 실증시험을 하는 단계까지 와 있는 실정이다. 국내에서도 한전 주관으로 실증시험을 그 목적으로 고창시험장에 100m급, 22.9kV/50MVA HTS-케이블이 설치되어 운전되고 있다. 이와 같이 다수본의 HTS-테이프로 구성되는 HTS-케이블에서 발생되는 교류손실은 HTS-케이블의 효율을 저하시킬 뿐만 아니라 냉동기비용 증가를 초래하지만 HTS-케이블 구조의 복잡성으로 인하여 교류손실에 대한 평가가 매우 난해하다. 따라서 본 논문에서는 고창HTS-케이블의 교류손실에 대하여 실험적 이론적 조사 및 검토를 하였다. 그 주요결과를 요약하면, 측정된 Bi도체의 교류손실에 대한 손실지수 ${\kappa}$는 약 2.5로 Cu 도체에서 발생하는 Ohmic손실의 지수(~2)와 비교하여 큰 것을 볼 수 있다. 또한 전기적인 방법으로 측정한 HTS-케이블의 총손실은 열량법으로 측정한 손실과 잘 일치한다.

  • PDF

Evaluation Standard on Talker Echo of ISDN Telephone (ISDN 전화기의 송화 에코 평가 기준)

  • 강경옥
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1993.06a
    • /
    • pp.50-53
    • /
    • 1993
  • ISDN에 기초한 음성 서비스가 가능해지고 망이 점차 광대역 ISDN으로 진화함에 따라, ISDN 전화기의 송화자 에코의 적절한 규정이 필요하며, 이는 ISDN 전화기의 송화 및 수화음량정격 및 단말결합손실에 의해 좌우된다. 따라서, 전화기의 송화 및 수화음량정격이 규정되어질 경우, 에코가 없는 전화통화를 할 수 있는 단말결합손실의 규정이 필요하며, 실질적으로 이에 대한 규정은 가중 단말결합손실(weighted terminal coupling loss ; TCLw)과 에코 안정손실(stability loss)로 분류되어 규정될 수 있다. 본고에서는 이와 관련된 국제기준을 고찰하고, 국내기준의 제안과 단말결합손실 및 안정손실의 측정결과에 대해서 기술한다.

  • PDF

Transmission Loss Allocation Considering Generation Increasing Patterns (발전량 증가 패턴을 고려한 송전 손실 배분 방법)

  • Moon, Hyung-Jun;Min, Kyung-Il;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.162-163
    • /
    • 2011
  • 송전손실 배분에 대한 방법 중에서 발전 증가 패턴에 따른 방법을 제시하였다. 손실 감도 계산을 통하여 모선별 계통 손실을 구한다. 기저점에서 동작점으로 증가해 갈 때의 송전 손실 배분에 대해서 공정하게 할 수 있는 알고리즘이다. 모선별 계통 손실은 적분 경로에 따라 달라지게 되고, 이에 따라 어떻게 달라지는 지 시뮬레이션을 통하여 알아보았다.

  • PDF

Decoupled TCP: TCP for Wireless Networks (무선 네트워크에 적합한 Decoupled TCP)

  • 강문수;모정훈
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.10c
    • /
    • pp.175-177
    • /
    • 2004
  • 무선망에서의 TCP 성능은 않은 연구가 되어 왔지만 손실율이 큰 경우의 TCP의 성능은 아직도 개선의 여지가 많다. 본 논문은 두 가지 점에서 새로운 TCP를 제안한다. 첫째, 혼잡제어(Congestion Control)와 손실제어(Loss Recovery)가 분리(Decoupled)되었다. 기존의 연구들은 무선손실과 혼잡손실을 구분하여야 한다는 점에는 많은 연구를 해왔지만 무선 손실에 대하여 어떻게 대처할 것 인가에 관한 문제는 상대적으로 간과하였다. 둘째, 기종의 TCP-Westwood와 TCP-Jersey에서 사용되는 ABE(Available Bandwidth Estimation)가 무선네트워크에 의해 발생하는 패킷 손실로 인해 부정확해지는 것을 지적하고 새로운 ABE방법을 제시한다. 시뮬레이션을 통하여 우수한 성능을 보여주었다.

  • PDF

재해손실 비용 분석 기법에 관한 연구

  • 권희봉;나승훈;김태호
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2000.11a
    • /
    • pp.111-111
    • /
    • 2000
  • 기업의 성장과 더불어 일반적으로 산업재해로 인한 손실비용이 증가하는 추세이며, 이는 기업이나 국가적으로 그 만큼의 이익분에 대한 손실로 발생되어진다. 영국의 경우 재해로 인한 손실비율이 기업이익의 5∼10%를 차지하고 있는 것으로 최근 조사되고 있다. 따라서 기업의 경쟁력 향상을 위하여 재해로 인한 경제적 손실비용의 정확한 파악과 분석이 요구되어지고 있다. 따라서 본 연구에서는 재해손실 비용의 파악과 그 분석 기법의 체계적 비교 조사 하였다.

  • PDF