DOI QR코드

DOI QR Code

Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units

3실 열펌프의 운전조합에 대한 난방성능 실험연구

  • Kim, Ju-Hyung (Department of Mechanical Engineering, Korea Polytechnic University) ;
  • Kim, Ki-Young (Department of Mechanical Engineering, Sunmoon University) ;
  • Kwon, Young-Chul (Department of Mechanical Engineering, Sunmoon University) ;
  • Park, Seung-Chul (Department of Mechanical Engineering, Korea Polytechnic University)
  • 김주형 (한국산업기술대학교 기계공학과) ;
  • 김기영 (선문대학교 기계공학과) ;
  • 권영철 (선문대학교 기계공학과) ;
  • 박승철 (한국산업기술대학교 기계공학과)
  • Received : 2013.08.12
  • Accepted : 2013.09.06
  • Published : 2013.09.30

Abstract

In order to investigate the heating performance of multi-heat pump applying an inverter compressor, the experiment on heat pump with 3 indoor units was performed under the heating standard and heating low-temperature conditions. The performance data of heat pump with 3 indoor units were measured by the multi-psychrometric calorimeter. The operation characteristics and the behavior of the refrigerant cycle of the heat pump with 3 indoor units were understood from the heating capacity, heating COP, and P-h diagram by indoor-unit combination. The present experimental results show that the operating load and performance of the multi-heat pump depends on the indoor-unit combination. The heating capacity and heating COP of the low temperature condition were smaller than those of the standard one. Also the refrigerant cycles on indoor-unit combination were analyzed by using P-h diagram.

Keywords

COP;Capacity;Heating;Heat pump;Indoor-unit;P-h diagram

References

  1. D. Y. Han, H. J. Kwon and S. C. Ha, "Design and performance prediction of the multi-type heat pump system," Proceeding of the SAREK, pp. 515-520, 1999
  2. H. H. Cho, Y. C. Kim and H. H. Park, "Performance characteristics of an inverter-driven scroll compressor," Proceeding of the air-conditioning and Refrigeration Engineering, pp.1139-1143, 1999
  3. G. H. Jung, H. D. Choi, M. H. Kim and S. K. Oh, "An optimal control using a compressor discharge temperature on multi-type inverter heat pump," Proceeding of the SAREK, pp. 1241-1246, 2002
  4. Korean Standards Service Network, KS C 9306 : KS Air Conditioner, 1999
  5. ASHRAE, "Method of Testing for Rating Room Air Conditioner and Packaged Terminal Air Conditioner Heating Capacity," ANSI/ASHRAE Standard 58-1986, 1986.
  6. V. Bahel and S. M. Zubair, "An assessment of inverter driven variable speed air conditioners: sample performance comparison with a conventional systems," ASHRAE Trans., Vol. 95, pp. 455-464 , 1989
  7. C. K. Rice and S. K. Fisher, "Comparative analysis of single and continuously variable-capacity heat pump concepts", Proc. of the DOE/ORNL Heat Pump Conference, pp. 57-65, 1985
  8. Y. C. Kwon, C. K. Chun, Y. C. Park, K. W. Ko and D. N. Seo, "Experimental Study on Cooling Performance of Multi-Heat Pump by Indoor-Unit Combination," Vol. 9, No. 6, pp. 1487-1493, 2008 DOI: http://dx.doi.org/10.5762/KAIS.2008.9.6.1487 https://doi.org/10.5762/KAIS.2008.9.6.1487