Abstract

To investigate the difference in the value of horizontal heterophoria measured in phoria test of about normal 72 college students, using both Von Graefe test and Maddox rod test. We used two different methods which are Von Graefe test and Maddox rod test on full correction condition at the long distance. Using Von Graefe test of horizontal heterophoria Measurement, We measured 21 patients(29%) for orthophoria, 36 patients(50%) for exophoria and 15 patients(21%) for esophoria at distance. Using Maddox rod test of horizontal heterophoria Measurement, We measured 36 patients(50%) for orthophoria, 26 patients(36%) for exophoria and 10 patients(14%) for esophoria at distance. Each test average were $0.93{\Delta}$ BI for Von Graefe test, $0.96{\Delta}$ BI for Maddox rod test. We could not find the definite difference about the value of horizontal heterophoria aby testing method. Furthermore, heterphoria AC/A ratio was found to vary from 1.0 to 8.8 and its relationship to refractive error could not be determined.

Keywords

Von Graefe test;Maddox rod test;horizontal heterophoria;exophoria