DOI QR코드

DOI QR Code

Preliminary Study of Performance Evaluation of a Dual-mode Compton Camera by Using Geant4

Geant4 몬테칼로 전산모사 툴킷을 이용한 이중모드 컴프턴 카메라 최적화 설계 및 성능평가

  • Received : 2012.08.17
  • Accepted : 2012.12.05
  • Published : 2012.12.31

Abstract

A double-scattering type Compton camera which is appropriate to imaging a high-energy gamma source has been developed for nuclear material surveillance at Hanyang University. The double-scattering type Compton camera can provide high imaging resolution; however, it has disadvantage of relatively low imaging sensitivity than existing single-scattering type Compton camera. In this study, we introduce a novel concept of a dual-mode Compton camera which incorporates two different types of Compton camera, i.e., single- and double-scattering type. The dual-mode Compton camera can operate high-resolution mode and high-sensitivity mode in a single system. To maximize its performance, the geometrical configuration was optimized by using Geant4 Monte Carlo simulation toolkit. In terms of imaging sensitivity, high-sensitivity mode had higher sensitivity than high-resolution mode up to 100 times while high imaging resolution of the double-scattering Compton camera was maintained.

Acknowledgement

Supported by : 한국연구재단

References

  1. Seo H, Kim CH, Park JH, Kim JK, Lee JH, Lee CS, Lee JS. Development of double-scattering-type Compton camera with double-sided silicon strip detectors and NaI(Tl) scintillation detector. Nucl. Instr. and Meth. A 2010;615:333-339. https://doi.org/10.1016/j.nima.2010.02.060
  2. Agostinelli S, Allison J, Amako K, et al. GEANT4-a simulation toolkit. Nucl. Instr. and Meth. A 2003; 560:250-303.
  3. Allison J, Amako K, Apostolakis J, et al. Geant4 developments and applications. IEEE Trans. Nucl. Sci. 2006;53:270-278. https://doi.org/10.1109/TNS.2006.869826
  4. Yang YF, Gono Y, Motomura S, Enomoto S, Yano Y. A Compton camera for multitracer imaging. IEEE Trans. Nucl. Sci. 2001;48:656-661. https://doi.org/10.1109/23.940142
  5. Wilderman SJ, Fessler JA, Clinthorne JA, et al. Improved modeling of system response in list mode EM reconstruction of compton scatter camera images. IEEE Trans. Nucl. Sci. 2001;48:111-116. https://doi.org/10.1109/23.910840
  6. 서희, 박진형, 김찬형, 이주한, 이춘식, 이재성. 이중산 란형 컴프턴 카메라 구성 검출기 성능평가. 방사선방어학회지 2010;35:69-76.
  7. Short course lecture note. Nuclear science for homeland security. 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference.

Cited by

  1. Development of Compton imaging system for nuclear material monitoring at pyroprocessing test-bed facility vol.53, pp.12, 2016, https://doi.org/10.1080/00223131.2016.1199333