Comparison of Non-Destructive Testing Images using $^{192}Ir$ and $^{75}Se$ with Computed Radiography System
Computed Radiography 시스템에 $^{192}Ir$ 과 $^{75}Se$ 동위원소를 적용하여 촬영한 비파괴검사 영상 비교
- Kang, Sang-Mook (Department of Nuclear Engineering, Hanyang University) ;
- Chol, Chang-Il (Department of Nuclear Engineering, Hanyang University) ;
- Lee, Seung-Kyu (Department of Nuclear Engineering, Hanyang University) ;
- Park, Sang-Ki (Korea Electric Power Research Institute) ;
-
Kim, Yong-Kyun
(Department of Nuclear Engineering, Hanyang University)
- Received : 2010.02.19
- Accepted : 2010.03.12
- Published : 2010.03.30
Abstract
A computed Radiography (CR) system by use of reusable Image Plate (IP) offers a convenient and reliable way to replace a conventional film-screen system for NDT (non-destructive testing) field. The quality of a radiography to detect a defect of welded objects depends on the procedure embracing several factors such as measurement conditions, image plate type/class, radiation energy, radiation type, and source to image plate distance. Also, the ability of images to detect a flaw reduces with increasing object thickness. In the study, the properties of gamma ray source were summarized for NDT field and inspection images of CR image system manufactured by FUJI were acquired using
Keywords
File
References
- Peter H. Radiography of welds using selenium 75, Ir 192 and X-rays. 12th Asia-Pacific Conference on NDT 2006.
- Mark GS. Advanced, Second-Generation Selenium 75 Gamma Radiography Sources. 15th World Conference on Non-destructive Testing 2000.
- Gregory AM, Peter W. Factors affecting probability of Detection with computed radiography. 17th World conference on Non-destructive Testing 2008.
- Uwe E, Uwe Z, Klaus B. Strategies for film replacement in radiography. IV Pan American Conference for Non Destructive Testing 2007.
- Steven AM. How to evaluate the radiographic performance and long-term stability of a computed radiography system. IV Pan American Conference for Non Destructive Testing 2007.
- http//ie.lbl.gov/education/isotopes.htm.
- Bruce HH. The physics of medical X-ray imaging. 2th ed. Wisconshin; medical physics publishing, 1991:1-10.