Journal of Radiation Protection and Research
- Volume 31 Issue 4
- /
- Pages.173-179
- /
- 2006
- /
- 2508-1888(pISSN)
- /
- 2466-2461(eISSN)
Application of Pulse Pile-Up Correction Spectrum to the Library Least-Squares Method
펄스 중첩 보정 스펙트럼의 라이브러리 최소자승법에의 이용
- Lee, Sang-Hoon (Department of Physics Kyungpook National University)
- 이상훈 (경북대학교 물리학과)
- Published : 2006.12.30
Abstract
The Monte Carlo simulation code CEARPPU has been developed and updated to provide pulse pile-up correction spectra for high counting rate cases. For neutron activation analysis, CEARPPU correction spectra were used in library least-squares method to give better isotopic activity results than the convention library least-squares fitting with uncorrected spectra.
File
References
- Ao Q, Lee SH, and Gardner RP. Error analysis of the in vivo XRF measurement of lead in bone by Monte Carlo simulation. Advances in X-ray Analysis 1999
- Todd AC, McNeill FE, and Fowler BA. In vivo X-ray fluorescence of lead in bone. Environ. Res. 59:326-335 https://doi.org/10.1016/S0013-9351(05)80039-8
- Preiss IL and Washington II W. Skin thickness effects on in vivo LXRF. Adv. X-ray Anal. 1995:38:607-613
- Gardner RP, Lee SH, Guo W, et al., CEARPPU: A Monte Carlo code for predicting pulse pile-up distortion for high counting-rate radiation spectra, PSR-528. Radiation Safety Information Computational Center, Oak Ridge National Laboratory, 2004
- Wielopolski L and Gardner RP. Prediction of the pulse-height spectral distortion caused by the peak pile-up effect Nucl. Instr. and Meth. 1976;133:303-309 https://doi.org/10.1016/0029-554X(76)90623-6
- Gardner RP and Wielopolski L. A generalized method for correcting pulse- height spectra for the peak pile-up effect due to double sum pulses: Part I. Predicting spectral distortion for arbitrary pulse shapes. Nucl. Instr. and Meth. 1977;140:289-296 https://doi.org/10.1016/0029-554X(77)90297-X
- Wielopolski L and Gardner RP. A generalized method for correcting pulse- height spectra for the peak pile-up effect due to double sum pulses: Part II. The inverse calculation for obtaining true from observed spectra. Nucl. Instr. and Meth. 1977;140:297-303 https://doi.org/10.1016/0029-554X(77)90298-1
- Bristow Q and Harrison RG. Theoretical and experimental investigations of the distortion in radiation spectra caused by pulse pileup. Nucl. Geophys. 1991;5:141-186
- ORTEC, Model 572 Spectroscopy Amplifier and Pile-Up Rejector Operating and Service Manual. 1982
- Knoll GF. Radiation Detection and Measurement. New York; Wiley, 1979