Atmospheric Dispersion Assessment for Potential Accidental Releases at Yonggwang Nuclear Power Plants
영광원전에서 가상 사고시 대기확산 평가
-
Na, Man-Gyun
(Chosun University) ;
- Sim, Young-Rok (Chosun University) ;
-
Jung, Chul-Kee
(Chosun University) ;
- Lee, Goung-Jin (Chosun University) ;
- Kim, Soong-Pyung (Chosun University) ;
- Chung, Sung-Tai (Korea Electric Power Company)
- Published : 2000.06.30
Abstract
XOQ_DW code is currently used to assess the atmospheric dispersion fur the routine releases of radioactive gaseous effluents at Yonggwang nuclear power plants. This code was developed based on XOQDOQ code and an additional code is required to assess the atmospheric dispersion for potential accidental releases. In order to assess the atmospheric dispersion fer the accidental releases, XOQAR code has been developed by using PAVAN code that is based on Reg. Guide 1.145. The terrain data of XOQ_DW code inputs and the relative concentrations (X/Q) of XOQ_DW code outputs are used as the inputs of the XOQAR code through the interface with XOQ_DW code. By using this code, the maximum values of X/Q at exclusion area and low population zone boundaries except for sea areas were assessed as