Improvement in the Control Performance of Instruments used for Minimally Invasive Surgery
Park, Hyeonjun; Won, Jongseok; Park, Jaeheung;
  PDF(new window)
 Abstract
This paper presents feedforward controllers to improve the control performance of the motion and grasping force of a surgical instrument used in an MIS (Minimally Invasive Surgery) robot. The surgical instrument has a long distance between the drive motors and its active joints. Therefore, the gripper on the instrument is controlled by a cable drive mechanism, which generates a coupled motion between the wrist joint and the grip direction. In order to solve the problem, this paper analyzes the pulley composition of the surgical instrument and proposes feedforward controllers to eliminate the coupled motion. Furthermore, feedforward controllers to regulate the grasping force are proposed to deal with another coupling problem between the grasping force of the instrument and the motion of the instrument joints. The experimental results demonstrate the improved control performance of the motion and grasping force of the instrument.
 Keywords
MIS (Minimally Invasive Surgery);surgical instrument;tendon driven;grasping force;
 Language
Korean
 Cited by
 References
1.
J. Rosen, B. Hannaford, and R. M. Satava (Editors), Surgical Robotics - Systems, Applications, and Visions, Springer, New York, 2011.

2.
S. H. Kim, K. G. Kim, and Y. H. Jo, "Laparoscope manipulator control for minimally invasive surgery," Journal of Institute of Control, Robotics and Systems (in Korean), vol. 17, no. 7, pp. 685-696, 2011. crossref(new window)

3.
J. Lee, S. Kim, Y. S. Kim, and W. K. Chung, "Automated Surgical Planning System for Spinal Fusion Surgery with Three-Dimensional Pedicle Model," Journal of Institute of Control, Robotics and Systems (in Korean), vol. 17, no. 8, pp. 807-813, 2011. crossref(new window)

4.
M. J. H. Lum, J. Rosen, M. N. Sinanan, and B. Hannaford, "Optimization of spherical mechanism for a minimally invasive surgical robot: Theoretical and experimental approaches," IEEE Transactions on Biomedical Engineering, vol. 53, no. 7, pp. 1440-1445, Jul. 2006. crossref(new window)

5.
G. T. Sung and I. S. Gill, "Robotic laparoscopic surgery: a comparison of the Da Vinci and Zeus systems," Urology, vol. 58, no. 6, pp. 893-898, 2001. crossref(new window)

6.
P. Puangmali, K. Althoefer, L. D. Seneviratne, D. Murphy, and P. Dasgupta, "State-of-the-art in force and tactile sensing for minimally invasive surgery," IEEE Sensors Journal, vol. 8, no. 4, pp. 371-381, Apr. 2008. crossref(new window)

7.
R. Ozawa, K. Hashirii, and H. Kobayashi, "Design and control of underactuated tendondriven mechanisms," IEEE International Conference on Robotics and Automation, pp. 1522-1527, May. 2009.

8.
B. Siciliano and O. Khatib, Springer Handbook of Robotics, Springer, New York, 2008.

9.
S. Ma, S. Hirose, and H. Yoshinada, "Design and experiments for a coupled tendon-driven manipulator," IEEE Control Systems, vol. 13, pp. 30-36, Feb. 1993.

10.
M. Feng, Y. Fu, B. Pan, and C. Liu, "A medical robot system for celiac minimally invasive surgery," IEEE International Conference on Information and Automation, pp. 33-38, Jun. 2011.